EPP2000 and ISA2000
Fiber Optic Spectrometer Manual
14390 Carlson Circle, Tampa, FL 34677 email: info@StellarNet-Inc.com
Phone 813-855-8687 fax 813-855-2279 web: www.StellarNet-Inc.com
Vista de pagina 0
1 2 3 4 5 6 ... 31 32

Indice de contenidos

Pagina 1 - EPP2000 and ISA2000

- 1 - EPP2000 and ISA2000 Fiber Optic Spectrometer Manual 14390 Carlson Circle, Tampa, FL 34677

Pagina 2 - StellarNet, Inc

- 10 - An optional Battery Power unit (BP1) is available for the EPP2000. It contains a 2.4 amp hour rating which will power the spectrometer f

Pagina 3 - Introduction

- 11 - SpectraWiz Software General Help //////////////////////////////////////////////////////////////// Experiment Procedures.."how to get

Pagina 4

- 12 - reflectance, using a fiber probe, hold at 45 deg to your white standard about 1/4 inch away. For cuvette holders, use cuvette i

Pagina 5 - - 5

- 13 - sample Same as menu File->Save->Sample (to disk) Save dark [picture of DARK light bulb] spectrum Used f

Pagina 6

- 14 - >> Centbase = level used to compute AreaPSD & Centroid. 2. Use right click to start dual cursor measurement for: AreaPSD, W

Pagina 7 - EPP2000 Hardware Interface

- 15 - SpectraWiz File Menu ////////////////////////////////////////////////////////////////// Save...current spectra sample dat

Pagina 8

- 16 - When multiple channels are enabled, a file -> save -> sample -> automatically saves all channels. This

Pagina 9 - EPP2000 Power Requirements

- 17 - SpectraWiz Setup Menu /////////////////////////////////////////////////////////////////// Detector integration time...sets new detector

Pagina 10 - - 10

- 18 - Spectral smoothing algorithm that avoids crushing peaks. First published in Analytical Chemistry - July 1964. Display Persist

Pagina 11

- 19 - Episodic data capture can be combined with the optical trigger function. First setup the trigger to operate in continuous mode

Pagina 12

- 2 - CC Declaration of Conformity According to EN45014 We StellarNet, Inc. Of 14390 Carlson Circle Tampa, Florida 33626 USA Declare unde

Pagina 13

- 20 - Map Logical to physical: If you have multiple spectrometers this provides a setup. This allows setup of the LU (Logical Unit) to

Pagina 14

- 21 - Use this option to tell the SpectraWiz software where the new hardware interface has been set. Once the new port has been

Pagina 15

- 22 - SpectraWiz View Menu ////////////////////////////////////////////////////////////////// Scope mode...displays uncompensated sp

Pagina 16

- 23 - reflection and is used for reflectance applications. Use transmission mode for SpectroColorimetry. Use a white light to refle

Pagina 17

- 24 - Setup range for watt and Rflux measurements: Specify the start and end wavelengths for the range computation of the total po

Pagina 18

- 25 - ////////////////////////////////////////////////////////////////// View -> Zoom: ON/OFF Allows a selected region to be expanded t

Pagina 19

- 26 - SpectraWiz Applications Menu ///////////////////// Applications ///////////////////////////// CIE Color Monitor...for SpectroCo

Pagina 20

- 27 - Pixel smoothing = level 4 Temperature compensation = ON Prior to enabling the colorimeter ensure that y

Pagina 21

- 28 - drift correction. A "ChemData.log" file allows users to quickly save samples for later viewing or printing. /////////////////

Pagina 22

- 29 - 299-328nm -> 1 * power(0.094 * (298-nm)) 329-400nm -> 1 * power(0.015 * (139-nm)) A "UVdata.log" file allows users to qu

Pagina 23

- 3 - Fiber Optic Spectrometer Manual Introduction______________________________________________________ 3 Quick Start Installation_________

Pagina 24

- 30 - Photo Diode Array - Application Note StellarNet spectrometers (EPP2000, EPP2000C, and ISA2000 models) equipped with a Toshiba PDA (Phot

Pagina 25

- 31 - Technical Support Bulletin, 11/17/99 Our software engineers have found a problem in the InstallShield program that prevents a key and it

Pagina 27

- 4 - Model EPP or ISA Wavelength range Resolution g/mm Grating 2000C-UV+VIS* 200-850nm 0.75nm 590, holographic-concave 2000-

Pagina 28

- 5 - Quick Installation for SpectraWiz Software Summary Installation for USB2EPP cable on Win98/ME/00/XP 1. If required, install adapter t

Pagina 29

- 6 - Installation for Win95/Win98/WinME Non-Plug-and-Play Interfaces The ISA2000 plug-in spectrometer and the EPP-ISA parallel port card f

Pagina 30

- 7 - Using the BIOS menus provided, change the port mode to EPP or EPP+ECP. Please note the mode cannot be set to the ECP only mode (or any ot

Pagina 31

- 8 - mode (The ECP mode is the Enhanced Capabilities Port mode and is the “Cadillac” mode) or it just doesn’t work perfectly like it should.

Pagina 32

- 9 - EPP2000 Special Interface Signals The above DB25 computer interface connector contains user defined signals specific for the EPP2000 spec